Search

695-200 Robertshaw 695-200 Integrated Furnace Control Board For Rheem 62-24268-01, 62-24268-02, 62-24268-03

Manufacturer: Robertshaw
Robertshaw 695-200 Integrated Furnace Control Board For Rheem 62-24268-01, 62-24268-02, 62-24268-03 Temperature Range 22 F to 149 F Gas Valve Contact: Output: 1.0 A @ 120 VAC, 60 Hz Heat Blower OFF Delay: 90/120/160/180 Sec Cool Blower ON Delay: 2 Seconds Humidity Range: 10 to 95% HSI Contact: Output: 5.0 A @ 120 VAC, 60 Hz Heat Blower ON Delay: 20 seconds Cool Blower OFF Delay: 45 Seconds
SKU: ROBERTSHAW:695-200
Product Availability: 7
$143.00
This product must be purchased in increments of 1
i h

 

Robertshaw 695-200 Integrated Furnace Control Board For Rheem 62-24268-01, 62-24268-02, 62-24268-03

 

Temperature Range 22 F to 149 F
Gas Valve Contact: Output: 1.0 A @ 120 VAC, 60 Hz
Heat Blower OFF Delay: 90/120/160/180 Sec
Cool Blower ON Delay: 2 Seconds
Humidity Range: 10 to 95%
HSI Contact: Output: 5.0 A @ 120 VAC, 60 Hz
Heat Blower ON Delay: 20 seconds
Cool Blower OFF Delay: 45 Seconds

Robertshaw 695-200 Integrated Furnace Control Board For Rheem 62-24268-01, 62-24268-02, 62-24268-03 The 695-200 is an exact replacement for the following Rheem/United Technologies part numbers: United Technologies 1012-925, 1012-925A, 1012-925B, 1012-925C, Rheem 62-24268-01, 62-24268-02, 62-24268-03 Product Benefits • Field selectable fan delay (90, 120, 160, 180 seconds) • High and low speed fan relay contacts • Output terminal for air cleaner, humidifier, or fresh aircontrol (120VAC) • Inducer pressure switch and thermal hi-limit failure detection • Captive screw terminals for thermostat connections • Microprocessor supervised for safe operation and accuracy • Automatic resetting lockouts ensure safety but eliminatenuisance calls • Electronic flame rectification sensing for safety and reliability • Speed-up test mode aids quick and thorough system checkout • Both sides conformal coated with acrylic for long life • Compatible with all 24VAC thermostats including powerstealing and battery operated units General Specifications Input voltage range low 18-30 VAC, 50/60 Hz Input voltage range high 85 to 135 VAC, 50/60 Hz Physical size (L x W x H) 6.0" x 4.5" x 1.0" Operating temperature range -22°F to 149°F Humidity range 10% to 95% Relative Humidity NC Air circulation blower output FLA 13.8A, LRA 26A @ 120 VAC Combustion inducer output FLA 2.2A, LRA 2.2A @ 120 VAC Electronic air cleaner output 1.0 A Resistive @ 120 VAC 60 Hz Gas valve contact output 1.0 A @ 120 VAC, 60 Hz HSI contact output 5.0 A @ 120 VAC, 60 Hz Thermostat terminations C, R, W, G, Y