Search

CARLIN GAS BURNER PRIMARY CONTROL 30/4/30

Manufacturer: Carlin
Carlin 60200FRS Flame Rod Gas Burner Primary Control For EZ-Gas & 201GAS Burners
SKU: CARLIN:60200FRS
Product Availability: 6
$124.74
This product must be purchased in increments of 1
i h

Carlin 60200FRS Flame Rod Gas Burner Primary Control For EZ-Gas, EZ-Gas Pro & 201GAS Burners. Now With LCD Screen! ***Important Note*** When Installing On A Covered Burner You Must Also Purchase The 33902FS Low Profile Junction Box. It Is NOT Included With This Control. Features: On-Board LCD Screen Easy to Understand Icons for Inputs and Outputs Displays micro-amp Flame reading Display operational information • Fault History records last 50 fault cycles to aid the technician in troubleshooting • Field Settable Timings • Pre-purge (0, 10, 30, 90) • Trial for Ignition Time (4, 6) • Post-Purge (0, 10, 15, 30, 60, 120) • Number of Recycles allowed (0, 1, 3) • Serviceman Reset Protection (3) • Low Voltage Terminals TT (can be programmed as Used or Not used) Blocked Vent input (contact closure, functions as a low voltage limit) CO input (contact closure) required to start C.F.H ., lockout if not detected during run Alarm output (dry contacts) 24VAC/DC Power input (red/white wire) 120 VAC, 60 HZ, 9 VA Limit circuit input (black wire) 120 VAC, 60 HZ Motor load (orange wire) 10 FLA / 60 LRA (reduce by valve and ignition load) Ignitor load (blue wire) 120 VAC, 60 HZ, 500 VA Valve load (violet wire) 2 amps Aux 120 VAC, 1 amp Alarm contacts (dry contacts) 24V, AC/DC, 2A Operating temperature limits +32°F to +140°F Storage temperature limits -40°F to +185°F Thermostat 24 VAC, 0.1A Blocked Vent 12 VDC. 2mA CO 12 VDC. 2mA Agencies UL recognized (US & Canada) Replaces Carlin 6020002FRS, 602000FRS, 60200-02FR, 6020002FR, 602002FR363S, 602002FR-363S

Carlin 60200FRS Flame Rod Gas Burner Primary Control For EZ-Gas, EZ-Gas Pro & 201GAS Burners. Now With LCD Screen! ***Important Note*** When Installing On A Covered Burner You Must Also Purchase The 33902FS Low Profile Junction Box. It Is NOT Included With This Control. Features: On-Board LCD Screen Easy to Understand Icons for Inputs and Outputs Displays micro-amp Flame reading Display operational information • Fault History records last 50 fault cycles to aid the technician in troubleshooting • Field Settable Timings • Pre-purge (0, 10, 30, 90) • Trial for Ignition Time (4, 6) • Post-Purge (0, 10, 15, 30, 60, 120) • Number of Recycles allowed (0, 1, 3) • Serviceman Reset Protection (3) • Low Voltage Terminals TT (can be programmed as Used or Not used) Blocked Vent input (contact closure, functions as a low voltage limit) CO input (contact closure) required to start C.F.H ., lockout if not detected during run Alarm output (dry contacts) 24VAC/DC Power input (red/white wire) 120 VAC, 60 HZ, 9 VA Limit circuit input (black wire) 120 VAC, 60 HZ Motor load (orange wire) 10 FLA / 60 LRA (reduce by valve and ignition load) Ignitor load (blue wire) 120 VAC, 60 HZ, 500 VA Valve load (violet wire) 2 amps Aux 120 VAC, 1 amp Alarm contacts (dry contacts) 24V, AC/DC, 2A Operating temperature limits +32°F to +140°F Storage temperature limits -40°F to +185°F Thermostat 24 VAC, 0.1A Blocked Vent 12 VDC. 2mA CO 12 VDC. 2mA Agencies UL recognized (US & Canada) Replaces Carlin 6020002FRS, 602000FRS, 60200-02FR, 6020002FR, 602002FR363S, 602002FR-363S

Products specifications
Used in EZGas Pro Burners
Used in 201 GAS BURNERS
Used in 301 GAS BURNERS
Used in 601 GAS BURNERS
Manufacturer Carlin
Customers who bought this item also bought
Picture of CARLIN UNIVERSAL GAS CONVERSION BURNER 50,000-275,000 BTU

CARLIN UNIVERSAL GAS CONVERSION BURNER 50,000-275,000 BTU

CARLIN:9859210FRU
SKU: CARLIN:9859210FRU
$872.69