Carlin 60200FRS Flame Rod Gas Burner Primary Control For EZ-Gas, EZ-Gas Pro & 201GAS Burners. Now With LCD Screen! ***Important Note*** When Installing On A Covered Burner You Must Also Purchase The 33902FS Low Profile Junction Box. It Is NOT Included With This Control. Features: On-Board LCD Screen Easy to Understand Icons for Inputs and Outputs Displays micro-amp Flame reading Display operational information • Fault History records last 50 fault cycles to aid the technician in troubleshooting • Field Settable Timings • Pre-purge (0, 10, 30, 90) • Trial for Ignition Time (4, 6) • Post-Purge (0, 10, 15, 30, 60, 120) • Number of Recycles allowed (0, 1, 3) • Serviceman Reset Protection (3) • Low Voltage Terminals TT (can be programmed as Used or Not used) Blocked Vent input (contact closure, functions as a low voltage limit) CO input (contact closure) required to start C.F.H ., lockout if not detected during run Alarm output (dry contacts) 24VAC/DC Power input (red/white wire) 120 VAC, 60 HZ, 9 VA Limit circuit input (black wire) 120 VAC, 60 HZ Motor load (orange wire) 10 FLA / 60 LRA (reduce by valve and ignition load) Ignitor load (blue wire) 120 VAC, 60 HZ, 500 VA Valve load (violet wire) 2 amps Aux 120 VAC, 1 amp Alarm contacts (dry contacts) 24V, AC/DC, 2A Operating temperature limits +32°F to +140°F Storage temperature limits -40°F to +185°F Thermostat 24 VAC, 0.1A Blocked Vent 12 VDC. 2mA CO 12 VDC. 2mA Agencies UL recognized (US & Canada) Replaces Carlin 6020002FRS, 602000FRS, 60200-02FR, 6020002FR, 602002FR363S, 602002FR-363S
Carlin 60200FRS Flame Rod Gas Burner Primary Control For EZ-Gas, EZ-Gas Pro & 201GAS Burners. Now With LCD Screen! ***Important Note*** When Installing On A Covered Burner You Must Also Purchase The 33902FS Low Profile Junction Box. It Is NOT Included With This Control. Features: On-Board LCD Screen Easy to Understand Icons for Inputs and Outputs Displays micro-amp Flame reading Display operational information • Fault History records last 50 fault cycles to aid the technician in troubleshooting • Field Settable Timings • Pre-purge (0, 10, 30, 90) • Trial for Ignition Time (4, 6) • Post-Purge (0, 10, 15, 30, 60, 120) • Number of Recycles allowed (0, 1, 3) • Serviceman Reset Protection (3) • Low Voltage Terminals TT (can be programmed as Used or Not used) Blocked Vent input (contact closure, functions as a low voltage limit) CO input (contact closure) required to start C.F.H ., lockout if not detected during run Alarm output (dry contacts) 24VAC/DC Power input (red/white wire) 120 VAC, 60 HZ, 9 VA Limit circuit input (black wire) 120 VAC, 60 HZ Motor load (orange wire) 10 FLA / 60 LRA (reduce by valve and ignition load) Ignitor load (blue wire) 120 VAC, 60 HZ, 500 VA Valve load (violet wire) 2 amps Aux 120 VAC, 1 amp Alarm contacts (dry contacts) 24V, AC/DC, 2A Operating temperature limits +32°F to +140°F Storage temperature limits -40°F to +185°F Thermostat 24 VAC, 0.1A Blocked Vent 12 VDC. 2mA CO 12 VDC. 2mA Agencies UL recognized (US & Canada) Replaces Carlin 6020002FRS, 602000FRS, 60200-02FR, 6020002FR, 602002FR363S, 602002FR-363S