                            Home
                        
                    
                    /
                
 
                                    - 
                        
                            1
                        
                        /
                        
                    
 
                
                - 
                    15 SEC INTERRUPTED DUTY CONTROL
                    
                        
                    
                    
                    
                
 
            
     
                        
                        
                            
                                15 SEC INTERRUPTED DUTY CONTROL
                            
                            
                                
                         
                        
                        
                            
                                Carlin 40200 Oil Primary Burner Control, 15 second TFI, 120 VAC
-  Power Input 120, 60Hz, 10VA
-  Motor Load 10 FLA, 60 LRA
-  Ignitor Load 120V, 60Hz, 500VA
-  Operating Temperature 32 to 140 F 
-  Thermostat Anticipator Current 0.1 A, AC 
Features 
-  Interrupted Duty Ignition
-  15-Second Trial for Ignition 40200 (1.3 second flame failure response time (FFRT)
-  30-Second Trial for Ignition 42230 (1.3 second flame failure response time (FFRT)
-  Recycle on flame Failure
-  Thermostat/Aquastat Compatible
-  SMC (Safety Monitoring Circuit) Technology
Replaces 40200-02S, 40200-02
                            
                        
                        
                        
                        
                        
                        
                        
                            
                            
                            
                            
                            
                            
                        
                        
                        
                            
                                
                                
                                
                                
                                
    
                                     
    
    
        
    
    
    
        This product must be purchased in increments of 1
    
    
                                
                                
                                
    
        
    
                                
                             
                            
                            
                         
                     
                 
                
                    
                        Carlin 40200 Oil Primary Burner Control, 15 second TFI, 120 VAC
- Power Input 120, 60Hz, 10VA
- Motor Load 10 FLA, 60 LRA
- Ignitor Load 120V, 60Hz, 500VA
- Operating Temperature 32 to 140 F 
- Thermostat Anticipator Current 0.1 A, AC
Features 
- Interrupted Duty Ignition
- 15-Second Trial for Ignition 40200 (1.3 second flame failure response time (FFRT)
- 30-Second Trial for Ignition 42230 (1.3 second flame failure response time (FFRT)
- Recycle on flame Failure
- Thermostat/Aquastat Compatible
- SMC (Safety Monitoring Circuit) Technology
Replaces 40200-02S, 40200-02