3P 120V 12A 1N/O 1N/C CONTACTR

Manufacturer: Square D
LC1D12G7 3P 120V 12A 1N/O 1N/C CONTACTR LC1D12G7 - Contact Current Rating 12A - Control Voltage 120V - Current Rating 12 Amp - Enclosure Type IP2X - Horse Power Rating 10 HP - Operating Temperature 23 to 140 F ( -5 to 60 C) - Mounting Type DIN Rail/Panel Mount - 3 Poles - Power Rating 7.5 kW - Voltage Rating 690V ; 300V Features: - New TeSys D Green increase TeSys D range with a new electronic coil with up to 80% less consumption than TeSys D standard AC or DC coil - New and patented TeSys D with Everlink termination technology available on 40A to 65A contactors and overload relays - Eliminates the time-consuming process of selecting tested combinations through web sites and spreadsheets. - Simple to select the right product - 3-pole and 4-pole contactor versions available - All contactors include built-in auxiliary contacts - All screw connections have IP20 finger-safe terminals with both North American and International terminal markings - TeSys D contactors can be panel mounted with screws or DIN rail mounted - TeSys D Green contactor simplify your maintenance services with 90% less references needed.TeSys D Green contactor associated with TeSys LR9D electronic overload relay reduces heat generation and energy consumption up to 50% - High-fault short circuit current ratings provide the flexibility to select any component, as long as it meets or exceeds the desired SCCR - TeSys D contactors are available with AC or DC operating coils - A choice of wiring connections, including spring terminals, ring tongue terminals, slip-on terminals and screw clamps, provides flexibility in meeting specific, application requirements - Class 10 or Class 20 bimetallic overload relays are available up to 140 A - Available with or without single-phase sensitivity for phase unbalance and phase loss protection - New solid state overload relays are available for 90 to 150 A application This 12A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 3HP at 200-208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 2HP at 240VAC single phase. When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 30A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.72 lbs. The TeSys D contactors and overload relays are the largest selling line of contactors and starters in the world. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry. TeSys D contactors are available in 11 contactor ratings for the USA market for inductive motor applications from 9 up to 150 full-load amps and resistive loads up to 200 A. Designed to control and provide overload protection to motors rated up to 100 HP at 480 VAC or 125 HP at 600 VAC, TeSys D meets your needs for a majority of motor starter applications. Read about TeSys D and Type 2 Coordinated Protection.
SKU: SQUARE D:LC1D12G7
Product Availability: 1
$155.61
This product must be purchased in increments of 1
i h

LC1D12G7 3P 120V 12A 1N/O 1N/C CONTACTR
LC1D12G7

- Contact Current Rating 12A
- Control Voltage 120V
- Current Rating 12 Amp
- Enclosure Type IP2X
- Horse Power Rating 10 HP
- Operating Temperature 23 to 140 F ( -5 to 60 C)
- Mounting Type DIN Rail/Panel Mount
- 3 Poles
- Power Rating 7.5 kW
- Voltage Rating 690V ; 300V

Features:
- New TeSys D Green increase TeSys D range with a new electronic coil with up to 80% less consumption than TeSys D standard AC or DC coil
- New and patented TeSys D with Everlink termination technology available on 40A to 65A contactors and overload relays
- Eliminates the time-consuming process of selecting tested combinations through web sites and spreadsheets.
- Simple to select the right product
- 3-pole and 4-pole contactor versions available
- All contactors include built-in auxiliary contacts
- All screw connections have IP20 finger-safe terminals with both North American and International terminal markings
- TeSys D contactors can be panel mounted with screws or DIN rail mounted
- TeSys D Green contactor simplify your maintenance services with 90% less references needed.TeSys D Green contactor associated with TeSys LR9D electronic overload relay reduces heat generation and energy consumption up to 50%
- High-fault short circuit current ratings provide the flexibility to select any component, as long as it meets or exceeds the desired SCCR
- TeSys D contactors are available with AC or DC operating coils
- A choice of wiring connections, including spring terminals, ring tongue terminals, slip-on terminals and screw clamps, provides flexibility in meeting specific, application requirements
- Class 10 or Class 20 bimetallic overload relays are available up to 140 A
- Available with or without single-phase sensitivity for phase unbalance and phase loss protection
- New solid state overload relays are available for 90 to 150 A application

This 12A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 3HP at 200-208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 2HP at 240VAC single phase. When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 30A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 120 VAC 50/60 Hz coil.

Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.72 lbs.

The TeSys D contactors and overload relays are the largest selling line of contactors and starters in the world. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry. TeSys D contactors are available in 11 contactor ratings for the USA market for inductive motor applications from 9 up to 150 full-load amps and resistive loads up to 200 A. Designed to control and provide overload protection to motors rated up to 100 HP at 480 VAC or 125 HP at 600 VAC, TeSys D meets your needs for a majority of motor starter applications. Read about TeSys D and Type 2 Coordinated Protection.

Products specifications
Manufacturer Square D