TRIPLE AQUASTAT RELAY LINE VOLT BURNER CONTROL 120V 60HZ. 13
TRIPLE AQUASTAT RELAY LINE VOLT BURNER CONTROL 120V 60HZ. 13
- 120V
- 60Hz
- Maximum Safe Operating Pressure 200 PSI on outside of immersion well, 100 psi on capsule if inserted directly.
- Maximum Safe Operating Pressure (kPa)1378 kPa on outside of immersion well, 690 kPa on capsule if inserted directly.
- Temperature Range Maximum 150 F at switches; 265 F at sensing element
- Includes 3 in. insertion well and ground screw.
- Mounting Vertical Mount
- Operating Humidity Range (% RH)0 to 95% RH, non-condensing
- Operating Temperature Range High Limit-- 130 F to 240 F adjustable; Low Limit-- 110 F to 220 F adjustable
- Differential Temperature High limit : 10 F fixed; low limit: 10-25 F adj
- Insulation Depth (in.)3 in.
Electrical Ratings, Burner At Full Load-- 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- 44.4 A @ 120 Vac: 22.2 A @ 240 Vac
Electrical Ratings, Circulator At Full Load-- 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- 44.4 A @ 120 Vac: 22.2 A @ 240 Vac
Features
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems.
- Provide multizone control by using a separate circulator and R845 Relay for each zone.
- Include diaphragm powerhead and Micro Switch assembly that respond to temperature changes in boiler water.
- Mount directly to boiler.
- Select models include large transformers and extra terminals for supplying power to low voltage zone valves.
- Require 24 Vac thermostat with heat anticipator set at 0.2 A (plus current draw of gas valve on L8124E).
Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service.
This product must be purchased in increments of 1
- 120V
- 60Hz
- Maximum Safe Operating Pressure 200 PSI on outside of immersion well, 100 psi on capsule if inserted directly.
- Maximum Safe Operating Pressure (kPa)1378 kPa on outside of immersion well, 690 kPa on capsule if inserted directly.
- Temperature Range Maximum 150 F at switches; 265 F at sensing element
- Includes 3 in. insertion well and ground screw.
- Mounting Vertical Mount
- Operating Humidity Range (% RH)0 to 95% RH, non-condensing
- Operating Temperature Range High Limit-- 130 F to 240 F adjustable; Low Limit-- 110 F to 220 F adjustable
- Differential Temperature High limit : 10 F fixed; low limit: 10-25 F adj
- Insulation Depth (in.)3 in.
Electrical Ratings, Burner At Full Load-- 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- 44.4 A @ 120 Vac: 22.2 A @ 240 Vac
Electrical Ratings, Circulator At Full Load-- 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- 44.4 A @ 120 Vac: 22.2 A @ 240 Vac
Features
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems.
- Provide multizone control by using a separate circulator and R845 Relay for each zone.
- Include diaphragm powerhead and Micro Switch assembly that respond to temperature changes in boiler water.
- Mount directly to boiler.
- Select models include large transformers and extra terminals for supplying power to low voltage zone valves.
- Require 24 Vac thermostat with heat anticipator set at 0.2 A (plus current draw of gas valve on L8124E).
Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service.