3-PHASE VOLT MON/ 190-480V/ AD

Manufacturer: Littlefuse
- Input Voltage 190 to 480 V - Maximum Input Power 6 - 50/60 Hz - Output Load Rating (VA) Pilot Duty: 480 VA @ 240 Vac B300; General Purpose: 10 A @ 240 Vac - Restart Delay Range 1 to 500 seconds adjustable - Trip Point Accuracy (%) ±1% - Overvoltage Trip Voltage (%) 110% - Overvoltage Reset Voltage (%) 107% - IP20 - NEMA 1 - Termination Type Torque: 6 in-lbs; Wire: Stranded or solid 12 - 20 AWG one per terminal - Operating Temperature -40° to 70°C (-40° to 158°F) - 3 Phase The 460 is a 3-phase voltage monitor that protects 190-480VAC or 475-600V, 50/60Hz motors regardless of size. The product provides a user selectable nominal voltage set point and the voltage monitor automatically senses line voltage. This unique microcontroller-based voltage and phase-sensing device constantly monitors the 3-phase voltages to detect harmful power line conditions such as low, high, and unbalanced voltage, loss of any phase, and phase reversal. When a harmful condition is detected, the 460 output relay is deactivated after a specified trip delay. The output relay reactivates after power line conditions return to an acceptable level for a specified amount of time (restart delay). The trip and restart delays prevent nuisance tripping due to rapidly fluctuating power line conditions. All 460 models feature adjustable 1-30 second trip delay, 1-500 second restart delay, 2-8% voltage unbalance trip point, and one form C contact except where noted.
SKU: LITTLEFUSE:460
Product Availability: Out of stock
$119.13
This product must be purchased in increments of 1
i h

- Input Voltage 190 to 480 V
- Maximum Input Power 6
- 50/60 Hz
- Output Load Rating (VA) Pilot Duty: 480 VA @ 240 Vac B300; General Purpose: 10 A @ 240 Vac
- Restart Delay Range 1 to 500 seconds adjustable
- Trip Point Accuracy (%) ±1%
- Overvoltage Trip Voltage (%) 110%
- Overvoltage Reset Voltage (%) 107%
- IP20
- NEMA 1
- Termination Type Torque: 6 in-lbs; Wire: Stranded or solid 12 - 20 AWG one per terminal
- Operating Temperature -40° to 70°C (-40° to 158°F)
- 3 Phase

The 460 is a 3-phase voltage monitor that protects 190-480VAC or 475-600V, 50/60Hz motors regardless of size. The product provides a user selectable nominal voltage set point and the voltage monitor automatically senses line voltage.

This unique microcontroller-based voltage and phase-sensing device constantly monitors the 3-phase voltages to detect harmful power line conditions such as low, high, and unbalanced voltage, loss of any phase, and phase reversal. When a harmful condition is detected, the 460 output relay is deactivated after a specified trip delay. The output relay reactivates after power line conditions return to an acceptable level for a specified amount of time (restart delay). The trip and restart delays prevent nuisance tripping due to rapidly fluctuating power line conditions.

All 460 models feature adjustable 1-30 second trip delay, 1-500 second restart delay, 2-8% voltage unbalance trip point, and one form C contact except where noted.

Products specifications
Manufacturer Littlefuse