REPLACES:
■ Rheem: 62-23599-01, 62-23599-02, 62-23599-03, 62-23599-04, 62-23599-05
FEATURES:
√ Direct Spark Ignition (DSI) control board
√ Microprocessor-based
√ Monitors timing, Trial for ignition, system switches, flame sensing & lockout
√ 100% lockout safety feature
√ Compatible with LP or natural gas
√ LED indication for status and fault codes to aid in troubleshooting
SPECIFICATIONS:
■ Inputs
• Voltage: 208-230 VAC, 50/60 Hz
• Control voltage: 18-30 VAC, 50/60 Hz
• System switches: Vent pressure, limit and MRLC (Manual Reset Limit Control)
■ Outputs
• Heat N.C.: 16FLA/30 LRA @ 277 VAC, 30K @ 85°C
• Cool N.O.: 15FLA/36 LRA @ 277 VAC, 100K @ 85°C
• Inducer: 9.8FLA/58.8LRA, 1/2HP @ 120 VAC, 6K @ 75°C
• Gas valve: 2.3 A PILOT DUTY @ 240 VAC, 6K @ 75°C
■ Heat Operation
• Pre-purge: 3 seconds
• Heat blower ON delay: 30 seconds
• Post-purge: 5 seconds
• Heat blower OFF delay: 90 seconds
• Ignition trial: 7 seconds
• Inter-purge (retrial): 15 seconds
• Ignition activation period: 5 seconds
• Flame establishing period: 2 seconds
• Flame failure response time: 0.8 seconds (maximum)
■ Fan Operation
• Heat blower ON: 1 second
• Heat blower OFF: 1 second
■ Cooling Operation
• Cool blower ON delay: 1 second
• Cool blower OFF delay: 30 seconds
■ Lockout Timing
• Auto reset lockout: 60 minutes