255 ICM OPEN BOARD FAN BLOWER CONTROL LOW COST OPEN BOARD
255 ICM OPEN BOARD FAN BLOWER CONTROL LOW COST OPEN BOARD
255 ICM OPEN BOARD FAN BLOWER CONTROL LOW COST OPEN BOARD
SPECIFICATIONS:
Input:
– Voltage: 18-30 VAC
Output:
– N.O.: 20 amps @ 240 VAC
– N.C.: 20 amps @ 240 VAC
Fixed Time Delays:
– ON: 1 second
– OFF: 60 seconds
Details
- Low cost open board design
- High power, relay output
- Dual function fan delay timer
- Controls the circulating fan in heat pump, A/C and forced air systems
- OFF delay purges ducts of residual air
- ON delay allows air to reach the proper comfort level prior to energizing the fan
Replaces
- A-1: 5893
- Bard: 8201-056
- Mars: 32574
- Rheem: 42-22515-01, 42-22515-02, 42-22515-03
- Snyder General/ICP: 1395336
Dual Function Fan Delay Timer
Power must be applied before and during the time delay period. When the initiate contact closes, the load energizes and remains energized as long as the initiate contact is closed. The time delay begins when the initiate contact opens. At the end of the time delay period, the load is turned off.
If the initiate contact recloses during the time delay period, the load remains energized, and the time delay is reset to zero. Removal of the input power during the delay turns off the load and resets the time delay to zero. A one-second interrogation delay is provided to avoid nuisance trips due to thermostat bounce or tampering.
This product must be purchased in increments of 1
255 ICM OPEN BOARD FAN BLOWER CONTROL LOW COST OPEN BOARD
SPECIFICATIONS:
Input:
– Voltage: 18-30 VAC
Output:
– N.O.: 20 amps @ 240 VAC
– N.C.: 20 amps @ 240 VAC
Fixed Time Delays:
– ON: 1 second
– OFF: 60 seconds
Details
- Low cost open board design
- High power, relay output
- Dual function fan delay timer
- Controls the circulating fan in heat pump, A/C and forced air systems
- OFF delay purges ducts of residual air
- ON delay allows air to reach the proper comfort level prior to energizing the fan
Replaces
- A-1: 5893
- Bard: 8201-056
- Mars: 32574
- Rheem: 42-22515-01, 42-22515-02, 42-22515-03
- Snyder General/ICP: 1395336
Dual Function Fan Delay Timer
Power must be applied before and during the time delay period. When the initiate contact closes, the load energizes and remains energized as long as the initiate contact is closed. The time delay begins when the initiate contact opens. At the end of the time delay period, the load is turned off.
If the initiate contact recloses during the time delay period, the load remains energized, and the time delay is reset to zero. Removal of the input power during the delay turns off the load and resets the time delay to zero. A one-second interrogation delay is provided to avoid nuisance trips due to thermostat bounce or tampering.