Search

VXT24 24V DIGITAL WATER FEEDER 1 TO 5 GALLON

Manufacturer: Hydrolevel
Max Pressure PSI: 150 24V 1/2" Size Features: - Digital Feed Counter - Brightly illuminated feed counter displays the amount of water added to the boiler — essential in diagnosing water loss problems that can severely shorten the life of a steam boiler. Built-in memory prevents power interruptions from clearing the counter. - Programmable Feed Delay - Helps prevent flooded boilers. Allows time for condensate to return to the boiler before starting a feed cycle — ensuring that additional water is needed. - Programmable Feed Amount Settings - Six settings provide two ways to feed. 1-5 gallon settings now feed above the probe to restore the boiler’s normal operating level. Or, select LWCO setting to end the feed cycle when the low water cut-off re-energizes the burner. - Manual Feed Button - Allows for additional make-up water at the touch of a button. Manual feed amounts are recorded and added to the total gallons displayed by the feed counter. - Underfeed Protection - If one feed cycle is not sufficient to restore boiler operation, the VXT will delay and feed one additional cycle. - Lockout Flood Protection - The VXT locks-out to prevent steam system flooding and costly water damage if burner operation does not resume after two consecutive feed cycles.
SKU: HYDROLEVEL:45-026
Product Availability: 1
$302.12
This product must be purchased in increments of 1
i h

24Vac Water Feeder with fully programmable delay before feed and feed settings (1 to 5 gallons) and Digital feed counter (Part Number 45-026)

 

Max Pressure PSI: 150
24V
1/2" Size

 

Features:
- Digital Feed Counter - Brightly illuminated feed counter displays the amount of water added to the boiler — essential in diagnosing water loss problems that can severely shorten the life of a steam boiler. Built-in memory prevents power interruptions from clearing the counter.

 

- Programmable Feed Delay - Helps prevent flooded boilers. Allows time for condensate to return to the boiler before starting a feed cycle — ensuring that additional water is needed.

 

- Programmable Feed Amount Settings - Six settings provide two ways to feed. 1- 5 gallon settings now feed above the probe to restore the boiler’s normal     operating level. Or, select LWCO setting to end the feed cycle when the low water   cut-off re-energizes the burner.

 

- Manual Feed Button - Allows for additional make-up water at the touch of a button. Manual feed amounts are recorded and added to the total gallons displayed by the feed counter.

 

- Underfeed Protection - If one feed cycle is not sufficient to restore boiler operation, the VXT will delay and feed one additional cycle.

 

- Lockout Flood Protection - The VXT locks-out to prevent steam system flooding and costly water damage if burner operation does not resume after two consecutive feed cycles.

 

Products specifications
Manufacturer Hydrolevel