Search

HONEYWELL 1 TWO STAGEAUTO COMBINATION DIAPHRAGM NATURALGAS V

Manufacturer: Honeywell
- Two Stage / Slow Opening - 120V - Temperature Range -40 to 150 F - Minimum -40 F - Capacity (CFH) 300 to 1000 - 1/2" PSI - 60hz - Maximum 150 F - Electric Connection 1/4" Spade Terminal & 30 " Leadwires with cover for electrical conduit connection. - 1" Pipe size NPT - 0.8" W.C. Low Stage - 3.5" W.C. High Stage - 0.077A Features - Slow opening B,C valve models are available for natural and LP gases respectively. - Valve closes on power failure; recommended for final shutoff service. - Valve closing time: 2 seconds maximum at 7 inches wc inlet pressure. - Valves rated for 0.5 pound per square inch (psi) (3.4 kPa). - Leadwires and cover for electrical conduit connections are provided. - V4944 is used with line voltage dual-stage thermostat or controller; V8944 is used with 24V dual-stage thermostat or controller. The V4943/V8943B and N (single stage) and V4944/V8944B and N (two stage) are solenoid-operated diaphragm valves suitable for natural gas only. The V4943/V8943C and V4944/V8944C and L are solenoid-operated diaphragm valves suitable for Liquefied Petroleum (LP) gas only. These valves are used on boilers, unit heaters, duct furnaces, makeup air and rooftop heaters.
SKU: HONEYWELL:V4944B1018
Product Availability: 1
$360.89
This product must be purchased in increments of 1
i h

- Two Stage / Slow Opening
- 120V
- Temperature Range -40 to 150 F
- Minimum -40 F
- Capacity (CFH) 300 to 1000
- 1/2" PSI
- 60hz
- Maximum 150 F
- Electric Connection 1/4" Spade Terminal & 30 " Leadwires with cover for electrical conduit connection.
- 1" Pipe size NPT
- 0.8" W.C. Low Stage
- 3.5" W.C. High Stage
- 0.077A

Features
- Slow opening B,C valve models are available for natural and LP gases respectively.
- Valve closes on power failure; recommended for final shutoff service.
- Valve closing time: 2 seconds maximum at 7 inches wc inlet pressure.
- Valves rated for 0.5 pound per square inch (psi) (3.4 kPa).
- Leadwires and cover for electrical conduit connections are provided.
- V4944 is used with line voltage dual-stage thermostat or controller; V8944 is used with 24V dual-stage thermostat or controller.

The V4943/V8943B and N (single stage) and V4944/V8944B and N (two stage) are solenoid-operated diaphragm valves suitable for natural gas only. The V4943/V8943C and V4944/V8944C and L are solenoid-operated diaphragm valves suitable for Liquefied Petroleum (LP) gas only. These valves are used on boilers, unit heaters, duct furnaces, makeup air and rooftop heaters.

Products specifications
Manufacturer Honeywell