YB230UV FIREYE CHASSIS, 230 VAC, 50/60 HZ WITH UV NON SELF-CHECK AMPLIFIER.

Manufacturer: Fireye
YB230UV FIREYE CHASSIS, 230 VAC, 50/60 HZ WITH UV NON SELF-CHECK AMPLIFIER. CHASSIS, 230 VAC, 50/60 HZ WITH UV NON SELF-CHECK AMPLIFIER. - 230 VAC - 50/60Hz - Total Connected Load Not To Exceed 2000 VA - Max Ambient Temp 140 F Features - A non-volatile memory allows the control to remember its history and present position even when power is interrupted. - A consistent flame signal read-out via display module or 4-20 mA output. - Read-out of main fuel operational hours and complete cycles via display module. - Modbus communications via RS485 multi-drop link. - Proof of fuel valve closure during the off cycle. - Burn-in time of program parameters occurs after 8 hours of main valve on time. - A run/check switch allows the operator to stop the program sequence in any of four different positions (Purge, PTFI, MTFI or Auto). - Remote Display mounting with NEMA 4 protection. - Remote Reset. - Programmable communication baud rate allows for DCS compatibility. - Keypad selectable language readout. - Revert to pilot can increase burner turn down. - Additional terminals provided for applications requiring additional inputs and outputs. The Fireye BurnerLogix System is a microprocessor-based burner management control system designed to provide the proper burner sequencing, ignition, and flame monitoring protection on automatically ignited oil, gas, and combination fuel burners. In conjunction with limit and operating controls, it programs the burner/blower motor, ignition, and fuel valves to provide for proper and safe burner operation. Through SMART LED’S, the control provides current operating status and lockout information in the event of a safety shutdown. Optional OLED and LCD displays are available that may be either plugged in or mounted remotely to give full language descriptors of current status and diagnostic lockout information. Refer to BurnerLogix PROGRAMMER SELECTION later in this document for the various combinations of programmer and display modules. A complete BurnerLogix system includes the YB110 (YB230) chassis equipped with the type of flame amplifier required for the application, appropriate flame detector, plug-in programmer module, wiring base and optional alpha-numeric display. Interchangeable programmer modules allow for complete versatility in selection of function, timing, and flame failure response times. The optional alpha-numeric display has 2 lines by 16 characters per line. It is available in either vacuum fluorescent or liquid crystal formats. The advantage of OLED is high brightness and extended temperature range down to –40°F. Both displays contain a fully functional keypad. You can easily scroll through the various menus to view the current operating status, review programmer configuration, and lockout history. When mounted remotely, the displays provide NEMA 4x(IP66) protection. An advantage of the BurnerLogix control family is the ability to set many of the operating parameters associated with proper and reliable burner operation allowing inventory of various programmer types to be kept to a minimum. The YB110 (YB230) is a chassis/flame amplifier module complete with mounting screws and blank display module. The display module BLV512 (OLED) or BLL510 (LCD), if required, must be ordered separately. Interchangeable YP programmer modules allow for complete versatility in selection of control function, timing, and flame scanning means. Functions such as pre-purge time, recycling or non-recycling interlocks, high fire proving interlock, and trial for ignition timing of the pilot and main flame are determined by the programmer module. The BurnerLogix system can be used with ultra-violet, auto-check infrared, flame rod, self-check ultra-violet flame scanners or direct coupled integrated scanners by choosing the proper chassis/flame amplifier module.
SKU: FIREYE:YB230UV
Product Availability: Out of stock
$1,196.33
This product must be purchased in increments of 1
i h

YB230UV FIREYE CHASSIS, 230 VAC, 50/60 HZ WITH UV NON SELF-CHECK AMPLIFIER.
CHASSIS, 230 VAC, 50/60 HZ WITH UV NON SELF-CHECK AMPLIFIER.

- 230 VAC
- 50/60Hz
- Total Connected Load Not To Exceed 2000 VA
- Max Ambient Temp 140 F

Features
- A non-volatile memory allows the control to remember its history and present position even when power is interrupted.
- A consistent flame signal read-out via display module or 4-20 mA output.
- Read-out of main fuel operational hours and complete cycles via display module.
- Modbus communications via RS485 multi-drop link.
- Proof of fuel valve closure during the off cycle.
- Burn-in time of program parameters occurs after 8 hours of main valve on time.
- A run/check switch allows the operator to stop the program sequence in any of four different positions (Purge, PTFI, MTFI or Auto).
- Remote Display mounting with NEMA 4 protection.
- Remote Reset.
- Programmable communication baud rate allows for DCS compatibility.
- Keypad selectable language readout.
- Revert to pilot can increase burner turn down.
- Additional terminals provided for applications requiring additional inputs and outputs.

The Fireye BurnerLogix System is a microprocessor-based burner management control system
designed to provide the proper burner sequencing, ignition, and flame monitoring protection on automatically ignited oil, gas, and combination fuel burners. In conjunction with limit and
operating controls, it programs the burner/blower motor, ignition, and fuel valves to provide for
proper and safe burner operation. Through SMART LED’S, the control provides current operating status and lockout information in the event of a safety shutdown. Optional OLED and LCD displays are available that may be either plugged in or mounted remotely to give full language descriptors of current status and diagnostic lockout information. Refer to BurnerLogix
PROGRAMMER SELECTION later in this document for the various combinations of
programmer and display modules.

A complete BurnerLogix system includes the YB110 (YB230) chassis equipped with the type
of flame amplifier required for the application, appropriate flame detector, plug-in programmer
module, wiring base and optional alpha-numeric display. Interchangeable programmer modules allow for complete versatility in selection of function, timing, and flame failure response times. The optional alpha-numeric display has 2 lines by 16 characters per line. It is available in either vacuum fluorescent or liquid crystal formats. The advantage of OLED is high brightness and extended temperature range down to –40°F. Both displays contain a fully functional keypad. You can easily scroll through the various menus to view the current operating status, review programmer configuration, and lockout history. When mounted remotely, the displays provide NEMA 4x(IP66) protection. An advantage of the BurnerLogix control family is the ability to set many of the operating parameters associated with proper and reliable burner operation allowing inventory of various programmer types to be kept to a minimum.

The YB110 (YB230) is a chassis/flame amplifier module complete with mounting screws and
blank display module. The display module BLV512 (OLED) or BLL510 (LCD), if required,
must be ordered separately. Interchangeable YP programmer modules allow for complete
versatility in selection of control function, timing, and flame scanning means. Functions such as
pre-purge time, recycling or non-recycling interlocks, high fire proving interlock, and trial for
ignition timing of the pilot and main flame are determined by the programmer module. The
BurnerLogix system can be used with ultra-violet, auto-check infrared, flame rod, self-check ultra-violet flame scanners or direct coupled integrated scanners by choosing the
proper chassis/flame amplifier module.

Products specifications
Manufacturer Fireye