UV1A6 FIREYE ULTRVIOLET SCANNER WITH 6FT FLEX

Manufacturer: Fireye
6' UV SCANNER, 1/2" NPT Lead wire Length 6 Feet Mount 1/2" NPT Fireye UV1A6 Ultraviolet Flame Sensor 1/2" NPT, 72" (1830mm) shielded leads Used With The Following Controls: Flame Monitor With EUV1 Amplifier Card MB-2 Series With 61-3359 UV Amplifier MicroM & M-Series II With MAUV1, MAUV1T, MEUV1, MEUV4 Amplifier Card D Series With 72DUV1 Amplifier PFM Adapter Kits PFM2UV, PFM3UV FlameWorx MBUV-300D, MBUV-310D Nexus NX3000, NX3100, NX4000, NX4100 Burner Logix YB110UV, YB230UV UV scanners are recommended for detecting flames from standard fuel gases, some waste gases and light oil fuels such as No. 2 oil. Flames from heavier oils can be detected with UV scanners but the unburned fuel shroud and/or atomization shroud can block passage of the UV from the flame zone to the UV tube, causing nuisance burner/boiler trips. Infrared detection is recommended for fuel oil heavier than No. 2, and some installations where waste gases are burned together with natural gas as a main flame. The UV tube is made of quartz and is filled with a gas that ionizes when struck by UV radiation from the flame. In the absence of UV radiation, the gas acts as an insulator between two electrodes which are mounted inside the tube. These electrodes are energized continuously by a high voltage. During combustion, UV radiation ionizes the gas, causing current pulses to flow between the electrodes. These current pulses result in a flame signal which is transmitted to the amplifier in the control, where it is processed to energize or hold in the flame relay. UV1A6
SKU: FIREYE:UV1A6
Product Availability: 6
$206.28
This product must be purchased in increments of 1
i h

6' UV SCANNER, 1/2" NPT

Lead wire Length 6 Feet
Mount 1/2" NPT

Fireye UV1A6 Ultraviolet Flame Sensor 1/2" NPT, 72" (1830mm) shielded leads

Used With The Following Controls: Flame Monitor With EUV1 Amplifier Card MB-2 Series With 61-3359 UV Amplifier MicroM & M-Series II With MAUV1, MAUV1T, MEUV1, MEUV4 Amplifier Card D Series With 72DUV1 Amplifier PFM Adapter Kits PFM2UV, PFM3UV FlameWorx MBUV-300D, MBUV-310D Nexus NX3000, NX3100, NX4000, NX4100 Burner Logix YB110UV, YB230UV

UV scanners are recommended for detecting flames from standard fuel gases, some waste gases and light oil fuels such as No. 2 oil. Flames from heavier oils can be detected with UV scanners but the unburned fuel shroud and/or atomization shroud can block passage of the UV from the flame zone to the UV tube, causing nuisance burner/boiler trips. Infrared detection is recommended for fuel oil heavier than No. 2, and some installations where waste gases are burned together with natural gas as a main flame.

The UV tube is made of quartz and is filled with a gas that ionizes when struck by UV radiation from the flame. In the absence of UV radiation, the gas acts as an insulator between two electrodes which are mounted inside the tube. These electrodes are energized continuously by a high voltage. During combustion, UV radiation ionizes the gas, causing current pulses to flow between the electrodes. These current pulses result in a flame signal which is transmitted to the amplifier in the control, where it is processed to energize or hold in the flame relay.

UV1A6

Products specifications
Manufacturer Fireye