EP260 FIREYE PROGRAM MODULE

Manufacturer: Fireye
10 & 15 Sec. TFI Recycle 30 Sec. Purge EP Programmer Module FIREYE PROGRAM MODULE The Fireye EP260, programmer module is used with the FLAME-MONITOR Burner Management Control System (P/N E110). Several operational characteristics of the programmer (with Engineering code 28 or later, e.g. 9414-28) are determined by six (6) dipswitches located on the side of the programmer. These characteristics include extended purge timing (dipswitches 3, 4, 5), and the option requiring the 3-P running interlock circuit to be proven open at the start of the operating cycle (dipswitch 6). Dipswitches 1 and 2 are inactive. The EP260,programmers provide start-up programming, safe-start check, and flame monitoring supervision. They insure proof of low fire position, and fuel valve end switch safety checks. The control is designed to initiate a safety lockout if any of these circuits are open at the improper point in the control cycle. A running interlock circuit on the FLAME-MONITOR system constantly monitors the limit switches, air flow switches, and fuel pressure switches through the programmer. The programmer will recycle if the running interlock circuit (3-P) is opened during the firing cycle. The programmer module will de-energize all fuel valve circuits within four (4) seconds (max.) following a flame failure , or at the end of the pilot trial for ignition period if no flame is detected. An alarm circuit will be energized following a safety lockout. The programmer module includes an RJ45 style connector to interface with an integral or remote alpha-numeric display (P/N ED510). It includes two (2) additional RJ style connectors to connect to an E500 Communication Interface in a multi-drop configuration. The programmer will also communicate with the E500 via the standard ED550 cables to provide backward compatibility. All EP programmers come equipped with built-in modbus-rtu communications. Refer to bulletin E-1101 for complete details. The programmer is the heart of the FLAME-MONITOR System and features a plug-in design for ease of installation. It is micro-processor based and stores burner cycles, burner hours, system hours, and lockout history (with burner cycle and burner hour time stamp) which are accessible via the ED510 alpha-numeric display, E500 Communication Interface or Modbus Communications. If replaced, the new programmer card will begin accumulating a new history. The EP programmer modules are used with the Fireye EB700 base chassis. They are installed in the chassis by inserting the EP programmer module into the second slot on the control. This slot is marked “Programmer Module” on the side of the chassis. The programmer module is designed to fit only in the proper slot. It cannot be snapped into place if inserted in the wrong location. DO NOT FORCE THEM. An amplifier model, display module (ED510) and flame scanner are also required for the FLAMEMONITOR control. The EP260, EP265, and EP270 programmers are compatible with both the ED500 and ED510 display modules. See “Programmer and Display Module Compatibility” later in this document. The Engineering code is located on the back side of the board in the lower right hand corner. POWERFLAME 398130
SKU: FIREYE:EP260
Product Availability: 1
$1,380.57
This product must be purchased in increments of 1
i h

10 & 15 Sec. TFI Recycle
30 Sec. Purge EP Programmer Module

FIREYE PROGRAM MODULE
The Fireye EP260, programmer module is used with the FLAME-MONITOR Burner Management Control System (P/N E110). Several operational characteristics of the programmer (with Engineering code 28 or later, e.g. 9414-28) are determined by six (6) dipswitches located on the side of the programmer. These characteristics include extended purge timing (dipswitches 3, 4, 5), and the option requiring the 3-P running interlock circuit to be proven open at the start of the operating cycle (dipswitch 6). Dipswitches 1 and 2 are inactive. The EP260,programmers provide start-up programming, safe-start check, and flame monitoring supervision. They insure proof of low fire position, and fuel valve end switch safety checks. The control is designed to initiate a safety lockout if any of these circuits are open at the improper point in the control cycle. A running interlock circuit on the FLAME-MONITOR system constantly monitors the limit switches, air flow switches, and fuel pressure switches through the programmer. The programmer will recycle if the running interlock circuit (3-P) is opened during the firing cycle. The programmer module will de-energize all fuel valve circuits within four (4) seconds (max.) following a flame failure , or at the end of the pilot trial for ignition period if no flame is detected. An alarm circuit will be energized following a safety lockout. The programmer module includes an RJ45 style connector to interface with an integral or remote alpha-numeric display (P/N ED510). It includes two (2) additional RJ style connectors to connect to an E500 Communication Interface in a multi-drop configuration. The programmer will also communicate with the E500 via the standard ED550 cables to provide backward compatibility.

All EP programmers come equipped with built-in modbus-rtu communications. Refer to bulletin

E-1101 for complete details. The programmer is the heart of the FLAME-MONITOR System and features a plug-in design for ease of installation. It is micro-processor based and stores burner cycles, burner hours, system hours, and lockout history (with burner cycle and burner hour time stamp) which are accessible via the ED510 alpha-numeric display, E500 Communication Interface or Modbus Communications. If replaced, the new programmer card will begin accumulating a new history.

The EP programmer modules are used with the Fireye EB700 base chassis. They are installed in the chassis by inserting the EP programmer module into the second slot on the control. This slot is marked “Programmer Module” on the side of the chassis. The programmer module is designed to fit only in the proper slot. It cannot be snapped into place if inserted in the wrong location. DO NOT FORCE THEM. An amplifier model, display module (ED510) and flame scanner are also required for the FLAMEMONITOR control. The EP260, EP265, and EP270 programmers are compatible with both the ED500 and ED510 display modules. See “Programmer and Display Module Compatibility” later in this document. The Engineering code is located on the back side of the board in the lower right hand corner.

POWERFLAME 398130

Products specifications
Manufacturer Fireye