Field Controls 46301402 PVO-300 4" Power Venter For Oil Systems Up To 2.25 GPH
Includes Pressure Switch And Post Purge Control
Included is one ETL and cETL listed Power Venter to
be used primarily with a single 120VAC controlled oil fired furnace, boiler, or
water heater. The PVO may be used to common vent multiple appliances with the addition
of a Control Kit. Please consult Field Control’s Technical Support for other
options.
ELECTRICAL RATINGS
|
MODEL
|
VAC
|
Hz
|
RPM
|
WATT
|
AMP
|
TP*
|
PVO-300
|
120
|
60
|
3000
|
145
|
2.1
|
YES
|
*Thermally Protected Motor
|
|
|
|
|
|
|
|
UNIT DIMENSIONS (INCHES)
|
MODEL
|
"H"
|
"W"
|
"D"
|
I/O**
|
PVO-300
|
7.5
|
9.25
|
7.0
|
4/4
|
**Inlet and Outlet Diameter
|
|
|
|
|
|
|
|
|
TYPICAL VENTING SYSTEM COMPONENTS
One PVO Series Power Venter with pre-wired controls;
adjustable post purge relay timer, adjustable draft proving switch, direct access terminal blocks,
and piping tee for multiple appliance systems.
•
Side Wall Vent Hood (Not included)
• Spill Switches (Not included)
• CK-Series Control Kit for multiple appliance venting (Not Included)
This device MUST be installed by a qualified agency in accordance
with the manufacturer's installation instructions.
The definition of a qualified agency is: any individual, firm, corporation or
company which either in person or through a representative is engaged in, and
is responsible for, the installation and operation of HVAC appliances, who is
experienced in such work, familiar with all the precautions required, and has
complied with all the requirements of the authority having jurisdiction.
The indoor mounted PVO Power Venter provides an economical power venting system for oil appliances. All controls are built into these units. A Vent Hood is required to terminate the vent system.
PVO300
Can Be Used To Replace Tjernlund HST-1, HSUL-1, HS1 in oil applicatrions
Field Controls 46301402 PVO-300 4" Power Venter For Oil Systems Up To 2.25 GPH
Includes Pressure Switch And Post Purge Control
Included is one ETL and cETL listed Power Venter to
be used primarily with a single 120VAC controlled oil fired furnace, boiler, or
water heater. The PVO may be used to common vent multiple appliances with the addition
of a Control Kit. Please consult Field Control’s Technical Support for other
options.
ELECTRICAL RATINGS
|
MODEL
|
VAC
|
Hz
|
RPM
|
WATT
|
AMP
|
TP*
|
PVO-300
|
120
|
60
|
3000
|
145
|
2.1
|
YES
|
*Thermally Protected Motor
|
|
|
|
|
|
|
|
UNIT DIMENSIONS (INCHES)
|
MODEL
|
"H"
|
"W"
|
"D"
|
I/O**
|
PVO-300
|
7.5
|
9.25
|
7.0
|
4/4
|
**Inlet and Outlet Diameter
|
|
|
|
|
|
|
|
|
TYPICAL VENTING SYSTEM COMPONENTS
One PVO Series Power Venter with pre-wired controls;
adjustable post purge relay timer, adjustable draft proving switch, direct access terminal blocks,
and piping tee for multiple appliance systems.
•
Side Wall Vent Hood (Not included)
• Spill Switches (Not included)
• CK-Series Control Kit for multiple appliance venting (Not Included)
This device MUST be installed by a qualified agency in accordance
with the manufacturer's installation instructions.
The definition of a qualified agency is: any individual, firm, corporation or
company which either in person or through a representative is engaged in, and
is responsible for, the installation and operation of HVAC appliances, who is
experienced in such work, familiar with all the precautions required, and has
complied with all the requirements of the authority having jurisdiction.
The indoor mounted PVO Power Venter provides an economical power venting system for oil appliances. All controls are built into these units. A Vent Hood is required to terminate the vent system.
PVO300
Can Be Used To Replace Tjernlund HST-1, HSUL-1, HS1 in oil applicatrions