Search

46123600 DI-5 DRAFT INDUCER FOR 14-20" PIPE

Manufacturer: Field Controls
DI-5 DRAFT INDUCER FOR 14-20" PIPE
SKU: FIELD CONTROLS:46123600
Product Availability: Out of stock
$1,119.53
This product must be purchased in increments of 1
i h

DI-5 DRAFT INDUCER FOR 14-20" PIPE

Field Draft Inducers solve the drafting problems caused by short chimneys, undersized flue pipes and negative building pressures.

Draft Inducers are designed for easy installation in a wide variety of applications, including oil or gas-fired furnaces, water heaters, and boilers. For venting single or multiple appliances, use a control kit.

DI Paks are available for 24 volt and millivolt applications and include all controls necessary.


When to use a Draft Inducer

• Long horizontal vent runs
• Undersized flue pipes
• Short chimneys
• Outside exposed chimney

How Draft Inducers Work

1. Thermostat calls for heat.
2. The Inducer control is activated. This energizes the Draft Inducer (A) which creates negative pressure or draft.
3. The draft closes the negative pressure proving switch and starts the burner (B).
4. When the thermostat is satisfied, both the burner and Draft Inducer shut down






Sizing Chart

Gas-Firing with Draft Hood

Gas-Firing with Barometric Draft Control

Oil or Coal-Firing with Barometric Draft Control

Input (BTU/HR)

Pipe Dia. (IN)

Draft Inducer (Model)

Static Pressure (IN W.C.)

Flow (CFM)

Input (BTU/HR)

Pipe Dia. (IN)

Draft Inducer (Model)

Static Pressure (IN W.C.)

Flow (CFM)

Max. Input per GPH

Pipe Dia. (IN)

Draft Inducer (Model)

Static Pressure (IN W.C.)

Flow (CFM)

69,000
105,000
111,000
120,000

3
4
5
6

DI-1

.04
.04
.06
.05

47
72
75
82

69,000
105,000
118,000
123,000

3
4
5
6

DI-1

.05
.05
.06
.05

36
55
65
68

.5
.7
.9
.95

3
4
5
6

DI-1

.05
.05
.05
.04

36
48
67
68

279,000
308,000
330,000
353,000

5
6
7
8

DI-2
DI-2 PK24*
DI-2 PKmv*

.06
.07
.11
.07

190
210
225
240

300,000
340,000
364,000
390,000

5
6
7
8

DI-2
DI-2 PK24
DI-2 PKmv

.07
.08
.09
.06

156
176
189
200

2
2.5
2.75
3

5
6
7
8

DI-2

.06
.07
.08
.05

156
175
200
215

522,000
674,000
694,000
835,000

8
9
10
12

DI-3

.18
.15
.12
.08

355
458
472
568

683,000
880,000
908,000
1,092,000

8
9
10
12

DI-3

.15
.13
.10
.06

355
458
472
568

5
6
6.5
7.5

8
9
10
12

DI-3

.13
.11
.09
.06

355
458
472
568

900,000
1,250,000
1,400,000
1,800,000

10
12
14
16

DI-4

.18
.20
.19
.15

612
850
952
1,224

1,177,000
1,635,000
1,831,000
2,300,000

10
12
14
16

DI-4

.15
.17
.16
.13

612
850
952
1,224

8.5
11
13
17

10
12
14
16

DI-4

.13
.14
.13
.10

612
850
952
1,224

2,000,000
2,200,000
2,400,000
2,800,000

14
16
18
20

DI-5

.14
.18
.10
.09

1,224
1,500
1,632
1,900

2,350,000
2,885,000
3,140,000
3,654,000

14
16
18
20

DI-5

.12
.15
.09
.08

1,224
1,500
1,632
1,900

17
21
22
26

14
16
18
20

DI-5

.10
.13
.07
.06

1,224
1,500
1,632
1,900

Note: Pressure switch required according to NFPA code.
Not for sidewall venting.



Replaces Tjernlund XL, TjernlundXLDI5

DI-5 DRAFT INDUCER FOR 14-20" PIPE

Field Draft Inducers solve the drafting problems caused by short chimneys, undersized flue pipes and negative building pressures.

Draft Inducers are designed for easy installation in a wide variety of applications, including oil or gas-fired furnaces, water heaters, and boilers. For venting single or multiple appliances, use a control kit.

DI Paks are available for 24 volt and millivolt applications and include all controls necessary.


When to use a Draft Inducer

• Long horizontal vent runs
• Undersized flue pipes
• Short chimneys
• Outside exposed chimney

How Draft Inducers Work

1. Thermostat calls for heat.
2. The Inducer control is activated. This energizes the Draft Inducer (A) which creates negative pressure or draft.
3. The draft closes the negative pressure proving switch and starts the burner (B).
4. When the thermostat is satisfied, both the burner and Draft Inducer shut down






Sizing Chart

Gas-Firing with Draft Hood

Gas-Firing with Barometric Draft Control

Oil or Coal-Firing with Barometric Draft Control

Input (BTU/HR)

Pipe Dia. (IN)

Draft Inducer (Model)

Static Pressure (IN W.C.)

Flow (CFM)

Input (BTU/HR)

Pipe Dia. (IN)

Draft Inducer (Model)

Static Pressure (IN W.C.)

Flow (CFM)

Max. Input per GPH

Pipe Dia. (IN)

Draft Inducer (Model)

Static Pressure (IN W.C.)

Flow (CFM)

69,000
105,000
111,000
120,000

3
4
5
6

DI-1

.04
.04
.06
.05

47
72
75
82

69,000
105,000
118,000
123,000

3
4
5
6

DI-1

.05
.05
.06
.05

36
55
65
68

.5
.7
.9
.95

3
4
5
6

DI-1

.05
.05
.05
.04

36
48
67
68

279,000
308,000
330,000
353,000

5
6
7
8

DI-2
DI-2 PK24*
DI-2 PKmv*

.06
.07
.11
.07

190
210
225
240

300,000
340,000
364,000
390,000

5
6
7
8

DI-2
DI-2 PK24
DI-2 PKmv

.07
.08
.09
.06

156
176
189
200

2
2.5
2.75
3

5
6
7
8

DI-2

.06
.07
.08
.05

156
175
200
215

522,000
674,000
694,000
835,000

8
9
10
12

DI-3

.18
.15
.12
.08

355
458
472
568

683,000
880,000
908,000
1,092,000

8
9
10
12

DI-3

.15
.13
.10
.06

355
458
472
568

5
6
6.5
7.5

8
9
10
12

DI-3

.13
.11
.09
.06

355
458
472
568

900,000
1,250,000
1,400,000
1,800,000

10
12
14
16

DI-4

.18
.20
.19
.15

612
850
952
1,224

1,177,000
1,635,000
1,831,000
2,300,000

10
12
14
16

DI-4

.15
.17
.16
.13

612
850
952
1,224

8.5
11
13
17

10
12
14
16

DI-4

.13
.14
.13
.10

612
850
952
1,224

2,000,000
2,200,000
2,400,000
2,800,000

14
16
18
20

DI-5

.14
.18
.10
.09

1,224
1,500
1,632
1,900

2,350,000
2,885,000
3,140,000
3,654,000

14
16
18
20

DI-5

.12
.15
.09
.08

1,224
1,500
1,632
1,900

17
21
22
26

14
16
18
20

DI-5

.10
.13
.07
.06

1,224
1,500
1,632
1,900

Note: Pressure switch required according to NFPA code.
Not for sidewall venting.



Replaces Tjernlund XL, TjernlundXL DI5
Products specifications
Manufacturer Field Controls