7505P1515U BECKETT GENISYS ADVANCED OIL BURNER CONTROL
7505P1515U BECKETT GENISYS ADVANCED OIL BURNER CONTROL
7505P1515U BECKETT GENISYS ADVANCED OIL BURNER CONTROL
Electrical Ratings
Inputs
- Voltage: 120 Vac nominal (102 to 132 Vac)
- Current: 100 mA nominal (150 mA max at 132 Vac)
- 60 Hz
Outputs
- Motor: 120 Vac, 10 full load amps (FLA*), 60 locked rotor amps
(LRA)
- Note – Reduce motor FLA rating by igniter current
- Igniter: 120 Vac, 3 A @ 0.7 PF min
- Solenoid Valve: 120 Vac, 1 A @ 0.7 PF min
- Thermostat Anticipator Current: 0.1 A
- Thermostat Voltage: 24 Vac
Application Ratings
- Oil Burner Input: < 20gph
- Control Programming: UL372 Group 2
Environmental Ratings
- Storage & Operating Ambient Temperature: -40°F to +150°F (-40°C to +65°C)
- Moisture: 5 to 95% RH, non-condensing and non-crystallizing
7505P1515U
- Lockout Time 15 sec
- Valve-On Delay Timer 15 sec
- Motor-off Delay Time 15 sec
Features & Benefits
- Water Resistant
- Thermostat and boiler control compatible
- Customizable pre-time and post-time
- Three status lights for system monitoring and diagnostics
- Welded relay protection with redundant motor relays
- Limited reset and limited recycle
- Sleek, modern design
- Technician Pump Prime mode
- 7505a replaces Honeywell R8184G
- 7505b replaces Honeywell R7184B
- Two communication ports for adding alarm contacts, programming display, and/or future
Replaces 7457, 7457U, R7184P1064 7505P-1515, 7505P1515
The Beckett GeniSys 7505 Oil Burner Control is a 120 VAC primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys 7505 is used with the GeniSys CAD Cell Flame Detector Kit 7006U to control the oil burner’s motor, igniter, and optional solenoid valve. It has front-mounted, 24 VAC thermostat terminals compatible with both mechanical and many power stealing thermostats. The control operates the burner with interrupted ignition with a 15 second lockout time.
This product must be purchased in increments of 1
7505P1515U BECKETT GENISYS ADVANCED OIL BURNER CONTROL
Electrical Ratings
Inputs
- Voltage: 120 Vac nominal (102 to 132 Vac)
- Current: 100 mA nominal (150 mA max at 132 Vac)
- 60 Hz
Outputs
- Motor: 120 Vac, 10 full load amps (FLA*), 60 locked rotor amps
(LRA)
- Note – Reduce motor FLA rating by igniter current
- Igniter: 120 Vac, 3 A @ 0.7 PF min
- Solenoid Valve: 120 Vac, 1 A @ 0.7 PF min
- Thermostat Anticipator Current: 0.1 A
- Thermostat Voltage: 24 Vac
Application Ratings
- Oil Burner Input: < 20gph
- Control Programming: UL372 Group 2
Environmental Ratings
- Storage & Operating Ambient Temperature: -40°F to +150°F (-40°C to +65°C)
- Moisture: 5 to 95% RH, non-condensing and non-crystallizing
7505P1515U
- Lockout Time 15 sec
- Valve-On Delay Timer 15 sec
- Motor-off Delay Time 15 sec
Features & Benefits
- Water Resistant
- Thermostat and boiler control compatible
- Customizable pre-time and post-time
- Three status lights for system monitoring and diagnostics
- Welded relay protection with redundant motor relays
- Limited reset and limited recycle
- Sleek, modern design
- Technician Pump Prime mode
- 7505a replaces Honeywell R8184G
- 7505b replaces Honeywell R7184B
- Two communication ports for adding alarm contacts, programming display, and/or future
Replaces 7457, 7457U, R7184P1064 7505P-1515, 7505P1515
The Beckett GeniSys 7505 Oil Burner Control is a 120 VAC primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys 7505 is used with the GeniSys CAD Cell Flame Detector Kit 7006U to control the oil burner’s motor, igniter, and optional solenoid valve. It has front-mounted, 24 VAC thermostat terminals compatible with both mechanical and many power stealing thermostats. The control operates the burner with interrupted ignition with a 15 second lockout time.