51531 BECKETT KIT IGNITER REPLACMNT PHELON TO HNYWL

Manufacturer: Beckett
Beckett 51531 Igniter And Primary Control Kit From Phelon All In One Control Kit Includes: Beckett 7505A0000C Genisys Control Beckett 51771U Ignitor Beckett 5770 4X4 Mounting Box Beckett 7006U Cad Cell Eye Leads Miscellaneous Wires And Accessories Beckett 51771U 120V Ignitor And Base Plate For A, AF, AFG And NX Oil Burners Specifications - 120V - 6 kV RMS - 20 kV Peak - 35 mA Contains Small Parts Kit Beckett 5988 Features & Benefits - UL recognized in the US and Canada (120 V only). - Small size and lightweight. - Adapts to multiple baseplates – making it the most versatile unit on the market. It will also fit on many other vendors’ transformer baseplates. - 20 kV peak rating guarantees quick and efficient ignition. - Vacuum encapsulation process using a synthetic resin provides resistance to moisture and excellent heat dissipation and electrical insulation. - Case material is a high-temperature thermoplastic that provides high impact strength and scratch resistance, and is impenetrable to most chemicals. - Case design has “breakout” sections at the rear and side for lead wire exit and a hood to neatly cover and protect these wires where required. Replaces - Beckett BLL101, Beckett 2-442, Beckett 5878U, Beckett 51936U - France 10SAY-04 5LAY-04 - Carlin 41000-S0-BK1 - Sid Harvey T92E - Allanson 2721-628, Allanson 2721-628G, Allanson 2721-628, Allanson 2721-628A, Allanson 2275-628G - Dongan XD-BK103, Dongan 75-A10-203 - KENYON SUPER C888 - France 5LAY-04, 98208 - Webster 3-28AB-BAF, PSI3-28AB-BAFR, Webster 3-28AB-BAFR - Sid Harvey T-92, - Grainger 51771GU, Grainger 4NY11 - Thermolok TB-10 - Reznor 220627, Reznor 101332 7505A0000C BECKETT OIL BURNER CONTROL GENISYS - 120V - Lockout 15 seconds - 60Hz - 0.1 Amps - Temp Range -40 to 150 F 7006U CAD CELL AF/G NX SR SF 15 LEAD. C554A1687 HONEYWELL 15" Lead The Beckett GeniSys Cadmium Sulfide (“CAD Cell”) Flame Detector Kit 7006U is used to detect the presence or absence of flame in residential and light commercial fuel oil burners. The 7006U CAD cell has a fast response time to detect flame failure and with a two-wire connection, easily connects to a primary safety control such as the GeniSys 7505 120V Primary Oil Burner Control or the latest GeniSys 7565 120V Oil Burner Advanced Primary Control. The 7006U CAD cell has a very high resistance in darkness and a very low resistance in the presence of light. The cad cell is used in various indoor (typically a basement) and outdoor environments that are typical for heating oil burners including, but not limited to, furnaces, boilers, domestic hot water tanks, pressure washers, and cracksealers. Beckett 7006U Cad Cell Eye And Leads For A, AF, AFG, NX, SR, SF Oil Burners 7006U Cad Cell Flame Detector 15" Lead. Honeywell Part Number C554A1687 Beckett 5770 Control Mounting Electrical Box, 4 x 4, For AF And AFG Burners This Is The Electrical Box Located Under The Primary Control The 51531 Kit Replaces Replaces Beckett 7147U, Honeywell R8119A1019, Honeywell R8991A1019, Carlin 4010002BKS, York 026-33079-700, Carlin 14280 R8991A
SKU: BECKETT:51531
Product Availability: 1
$238.98
This product must be purchased in increments of 1
i h

Beckett 51531 Igniter And Primary Control Kit From Phelon All In One Control

Kit Includes:
Beckett 7505A0000C Genisys Control
Beckett 51771U Ignitor
Beckett 5770 4X4 Mounting Box
Beckett 7006U Cad Cell Eye
Leads Miscellaneous Wires And Accessories

Beckett 51771U 120V Ignitor And Base Plate For A, AF, AFG And NX Oil Burners

Specifications
- 120V
- 6 kV RMS
- 20 kV Peak
- 35 mA

Contains Small Parts Kit Beckett 5988

Features & Benefits
- UL recognized in the US and Canada (120 V only).
- Small size and lightweight.
- Adapts to multiple baseplates – making it the most versatile unit on the market. It will also fit on many other vendors’ transformer baseplates.
- 20 kV peak rating guarantees quick and efficient ignition.
- Vacuum encapsulation process using a synthetic resin provides resistance to moisture and excellent heat dissipation and electrical insulation.
- Case material is a high-temperature thermoplastic that provides high impact strength and scratch resistance, and is impenetrable to most chemicals.
- Case design has “breakout” sections at the rear and side for lead wire exit and a hood to neatly cover and protect these wires where required.

Replaces
- Beckett BLL101, Beckett 2-442, Beckett 5878U, Beckett 51936U
- France 10SAY-04 5LAY-04
- Carlin 41000-S0-BK1
- Sid Harvey T92E
- Allanson 2721-628, Allanson 2721-628G, Allanson 2721-628, Allanson 2721-628A, Allanson 2275-628G
- Dongan XD-BK103, Dongan 75-A10-203
- KENYON SUPER C888
- France 5LAY-04, 98208
- Webster 3-28AB-BAF, PSI3-28AB-BAFR, Webster 3-28AB-BAFR
- Sid Harvey T-92,
- Grainger 51771GU, Grainger 4NY11
- Thermolok TB-10
- Reznor 220627, Reznor 101332


7505A0000C BECKETT OIL BURNER CONTROL GENISYS

- 120V
- Lockout 15 seconds
- 60Hz
- 0.1 Amps
- Temp Range -40 to 150 F

7006U CAD CELL AF/G NX SR SF 15 LEAD. C554A1687 HONEYWELL

15" Lead

The Beckett GeniSys Cadmium Sulfide (“CAD Cell”) Flame Detector Kit 7006U is used to detect the presence or absence of flame in residential and light commercial fuel oil burners. The 7006U CAD cell has a fast response time to detect flame failure and with a two-wire connection, easily connects to a primary safety control such as the GeniSys 7505 120V Primary Oil Burner Control or the latest GeniSys 7565 120V Oil Burner Advanced Primary Control. The 7006U CAD cell has a very high resistance in darkness and a very low resistance in the presence of light.

The cad cell is used in various indoor (typically a basement) and outdoor environments that are typical for heating oil burners including, but not limited to, furnaces, boilers, domestic hot water tanks, pressure washers, and cracksealers.

Beckett 7006U Cad Cell Eye And Leads For A, AF, AFG, NX, SR, SF Oil Burners 7006U Cad Cell Flame Detector 15" Lead. Honeywell Part Number C554A1687

Beckett 5770 Control Mounting Electrical Box, 4 x 4, For AF And AFG Burners This Is The Electrical Box Located Under The Primary Control

The 51531 Kit Replaces
Replaces Beckett 7147U, Honeywell R8119A1019, Honeywell R8991A1019, Carlin 4010002BKS, York 026-33079-700, Carlin 14280 R8991A

Products specifications
Manufacturer Beckett